![Desco](/img/default-banner.jpg)
- 110
- 345 284
Desco
United States
Приєднався 25 січ 2010
Desco Industries, Inc. | ESD Control Industry Experts | Manufacturer
Established in 1979, DII is the industry leader and manufacturer ESD control products and now includes over 12 different brands.
DII manufactures ESD control products. Product include:
shielding bags | wrist straps | ESD worksurfaces | ESD floor matting | laminates | foot grounders | groundable smocks | static dissipative gloves | ESD flooring | ionizers | continuous monitors | testers | ESD tape | dispensing bottles | document holders | other workbench accessories.
DII also manufactures non-ESD products including:
chemicals | grounding | personnel identification | material handling | time and attendance services | training products | cleanroom services | medical device assembly and manufacturing
For more information, contact Desco Industries, Inc. :
Website: www.Desco.com (desco.descoindustries.com)
E-Mail: Service@Desco.com
Phone: West Coast: (909) 627-8178 | East Coast: (781) 821-8370
Established in 1979, DII is the industry leader and manufacturer ESD control products and now includes over 12 different brands.
DII manufactures ESD control products. Product include:
shielding bags | wrist straps | ESD worksurfaces | ESD floor matting | laminates | foot grounders | groundable smocks | static dissipative gloves | ESD flooring | ionizers | continuous monitors | testers | ESD tape | dispensing bottles | document holders | other workbench accessories.
DII also manufactures non-ESD products including:
chemicals | grounding | personnel identification | material handling | time and attendance services | training products | cleanroom services | medical device assembly and manufacturing
For more information, contact Desco Industries, Inc. :
Website: www.Desco.com (desco.descoindustries.com)
E-Mail: Service@Desco.com
Phone: West Coast: (909) 627-8178 | East Coast: (781) 821-8370
Mini Monitor Installation Tutorial | DESCO
The Desco Mini Monitor is the newest generation of ESD continuous monitor. It uses a unique illuminated enclosure to indicate the status of the operator and worksurface. Green indicates proper grounding of the operator and worksurface, red indicates a failure, and blue indicates when the operator port is vacant. Other new features include the ParkSnap™, mat monitor disablement, magnetic mounting accessory, and audible alarm volume adjustment.
Click here to learn more about the Desco Mini Monitor:
desco.descoindustries.com/Mini-Monitor.aspx
Contact Desco for more information.
E-mail: Service@Desco.com
Phone: (909) 627-8178
Website: Desco.com
© 2024 Desco is a brand of DESCO INDUSTRIES INC
Click here to learn more about the Desco Mini Monitor:
desco.descoindustries.com/Mini-Monitor.aspx
Contact Desco for more information.
E-mail: Service@Desco.com
Phone: (909) 627-8178
Website: Desco.com
© 2024 Desco is a brand of DESCO INDUSTRIES INC
Переглядів: 514
Відео
Mini Monitor Product Tutorial | DESCO
Переглядів 5222 місяці тому
The Desco Mini Monitor is the newest generation of ESD continuous monitor. It uses a unique illuminated enclosure to indicate the status of the operator and worksurface. Green indicates proper grounding of the operator and worksurface, red indicates a failure, and blue indicates when the operator port is vacant. Other new features include the ParkSnap™, mat monitor disablement, magnetic mountin...
EMIT SmartLog Pro® 2 - Configuring the Proximity Reader
Переглядів 4918 місяців тому
The EMIT SmartLog Pro® 2 verifies the functionality of an operator’s wrist strap and footwear, logs the test results, and controls access to an ESD Protected Area. All operator test activity is logged into the SmartLog Pro® Manager Web App to meet the ANSI/ESD S20.20 requirements for an ESD Control Plan. The app is installed onto one server and accessed via a web browser. Each log entry include...
Desco Combo Tester X3 & EMIT 50426 Limit Comparator - Calibration Tutorial
Переглядів 5289 місяців тому
Frequency of re-calibration should be based on the critical nature of those ESD sensitive items handled and the risk of failure for the ESD protective equipment and materials. In general, EMIT recommends that calibration be performed annually. Use the EMIT 50426 Limit Comparator to perform periodic verification (once every 6-12 months) of the Desco Combo Tester X3 and EMIT SmartLog Pro® 2. The ...
Desco Pencil Ionizer - Installation Tutorial
Переглядів 40911 місяців тому
The Desco Pencil Type Ionizer uses compressed clean dry air (CDA) to neutralize electrostatic charges and dislodge dust and debris in tight, compact spaces. It is an ideal choice when cleaning parts and assemblies in electronic, medical device, and semiconductor applications. It is commonly used in applications such as mobile phone manufacturing, PCB assembly, watch making, and the cleaning of ...
EMIT SmartLog Pro® 2 + Alvarado EDC Turnstile - Installation Tutorial
Переглядів 22911 місяців тому
When paired with the EMIT SmartLog Pro® 2, the Alvarado EDC Waist High Turnstile controls access to the ESD Protected Area to operators that have passed their pre-defined ESD tests and have been granted access to the area. The Alvarado EDC turnstile is made of high-quality stainless steel and investment cast components. Designed to provide years of trouble-free operation, the turnstile rotates ...
EMIT ESD Glove Test Fixture - Product Tutorial with SmartLog Pro® 2
Переглядів 208Рік тому
The EMIT 50755 Glove Test Fixture is designed to be used with the SmartLog Pro® 2 and Combo Tester X3 to test operators that wear ESD gloves or finger cots per Compliance Verification ESD TR53. The Test Fixture is made with a stainless steel electrode that creates a larger test surface area allowing the path-to-ground of the operator wearing gloves or finger cots to be measured. Click here to l...
EMIT Contactless Test Switch - Product Tutorial with SmartLog Pro® 2
Переглядів 128Рік тому
The EMIT 50756 Contactless Test Switch is designed to be used with the SmartLog Pro® 2, Combo Tester X3, and Combo Tester X3 Plus to test operators that wear foot grounders or dual-wire wrist straps. An infrared sensor overrides the test switch on the personnel tester and allows operators to perform tests without contact. The contactless test switch will only work with dual-wire (conductor) wri...
Do Wireless Wrist Straps Actually Work? | Desco ESD Myths
Переглядів 7 тис.Рік тому
ESD MYTHS : A video series addressing and disproving myths found in the field of ESD (ElectroStatic Discharge) Control. In this video we disprove a trending ESD product: Do wireless wrist straps actually work? Click here to view our catalog of ESD Control wrist straps: desco.descoindustries.com/DescoCatalog/Wrist-Straps-Coil-Cords/ Contact DESCO for more information: E-mail: Service@Desco.com P...
Desco Shock Cord Foot Grounder - Product Overview
Переглядів 372Рік тому
The Desco 17255 Shock Cord Foot Grounder electrically grounds a user who may be working in an environment where static electricity might otherwise build up on the user and damage sensitive electronic devices being handled by the user. Two foot grounders are recommended for reliable grounding and ESD protection, providing ground when one foot is off the floor. Operator is grounded when foot is i...
EMIT SmartLog Pro® 2 - Calibration Tutorial
Переглядів 600Рік тому
The EMIT SmartLog Pro® 2 verifies the functionality of an operator’s wrist strap and footwear, logs the test results, and controls access to an ESD Protected Area. All operator test activity is logged into the SmartLog Pro® Manager Web App to meet the ANSI/ESD S20.20 requirements for an ESD Control Plan. The app is installed onto one server and accessed via a web browser. Each log entry include...
EMIT SmartLog Pro® 2 - Installation Overview
Переглядів 1,2 тис.Рік тому
The SmartLog Pro® 2 verifies the functionality of an operator’s wrist strap and footwear, logs the test results, and controls access to an ESD Protected Area. Each log entry includes operator identification, test results, resistance measurements, time, temperature, and humidity. All operator test activity is logged into a database to meet the ANSI/ESD S20.20 requirement for “Compliance verifica...
Desco 98133 AC Outlet Analyzer & Wrist Strap Tester | Product Overview
Переглядів 766Рік тому
The Desco AC Outlet Analyzer and Wrist Strap Tester verifies the proper wiring of AC outlets, provides a grounding point, and tests the path-to-ground integrity of an operator’s wrist strap. Visual and audible indicators display pass and fail conditions for the outlet and pass condition for the wrist strap. When plugged into an AC outlet, the green LED illuminates to confirm that both the outle...
Desco Full-Time Continuous Monitor - Product Tutorial
Переглядів 753Рік тому
Desco Full-Time Continuous Monitor - Product Tutorial
Desco Full-Time Continuous Monitor - Installation Tutorial
Переглядів 1,3 тис.Рік тому
Desco Full-Time Continuous Monitor - Installation Tutorial
SmartLog Pro® Manager - SmartLog Pro® SE Settings
Переглядів 4032 роки тому
SmartLog Pro® Manager - SmartLog Pro® SE Settings
SmartLog Pro® Manager Software Upgrades
Переглядів 2972 роки тому
SmartLog Pro® Manager Software Upgrades
Statguard Flooring - 46006 Body Voltage Meter
Переглядів 4572 роки тому
Statguard Flooring - 46006 Body Voltage Meter
FreeStyle 8400™ Floor Installation Guide | Statguard Flooring
Переглядів 4612 роки тому
FreeStyle 8400™ Floor Installation Guide | Statguard Flooring
Desco Dual Operator Continuous Monitor - Product Tutorial
Переглядів 4312 роки тому
Desco Dual Operator Continuous Monitor - Product Tutorial
SmartLog Pro® Manager Scheduled Reports
Переглядів 2352 роки тому
SmartLog Pro® Manager Scheduled Reports
Desco Dual Operator Continuous Monitor - Installation Overview
Переглядів 5552 роки тому
Desco Dual Operator Continuous Monitor - Installation Overview
Trustat® 19550 Benchtop AC Ionizer - Product Overview
Переглядів 3752 роки тому
Trustat® 19550 Benchtop AC Ionizer - Product Overview
Desco Digital Static Field Meter and Ionization Verification Kit
Переглядів 3,5 тис.2 роки тому
Desco Digital Static Field Meter and Ionization Verification Kit
EMIT - 50748 Face Recognition Terminal
Переглядів 8222 роки тому
EMIT - 50748 Face Recognition Terminal
Desco - 19494 Portable Charged Plate Monitor
Переглядів 1,3 тис.2 роки тому
Desco - 19494 Portable Charged Plate Monitor
el valor para la RTG debe ser < 1.0 x10^9 ohms???
Well done
Cuál es el voltaje que aplica el equipo para la medición del piso?
El medidor cambiará automáticamente su voltaje de prueba de 10 V a 100 V cuando la resistencia medida sea de 1 x 10⁶ ohmios o más para cumplir con el procedimiento de prueba descrito en ESD TR53.
Hi, how do you measure the ground point itself?
Still sounds like a bit of hogwash. I mean how is this used practically in our every day lives?
There are so many variables for this! If we eat low energy foods we omit lower frequency, same can be said what we drink. We also give away energy on a daily basis, toxic environment, energy vampires, pollution on the other hand their are so many ways to generate energy in the body, 1000's of years ago we were practicing such techniques, thats why they choose to hide the knowledge, but now its being revealed.
thanks
William reich,and larvahosky,both claimed a perfect young healy cell is 100mv, a healthy old person is 60mv, and a sick person with cancer is 15 to 20mv.they could cure people and reverse aging just by bringing the voltages back up to 100mv,they did that with the lahvasky multi wave oscillator.or the orgone accumulator,,any thoughts on this?
What is better? A copper needle or a stainless steel needle.
We do not have any data on copper emitters; however, stainless steel is inferior to tungsten. Tungsten emitters do not rust nor experience any other excessive degradation. This property makes them a popular choice for use in in ISO Class 1 or cleaner environments. All Desco ionizers use tungsten emitters.
How loud is it
Does the orientation of the mat matter? we have a mat that is blue on both sides and it is unclear what side should be up.
How many prizes
Do I need to use 2 strips of copper for this to work?. I have a 5×7 room to do this in.
Per our 8400 Series Vinyl Floor Tile Installation Instructions (TB-9032), Ground Strips should be installed prior to application of the conductive adhesive and tile, which will be applied directly on top of the copper strips. Identify the proper locations for the strips, typically along the base of walls or at columns where there is access to a grounding point (e.g., electrical outlet). Install one (1) ground strip for each 1,000 square feet of floor area, with a minimum of two (2) in any individual room.
thanks, sir.
They say grounding is good for health. So, should one stand on earth with a moist surface (wet earth) ? Won't the grounding be achieved if the surface is dry?
We specialize in making personnel ground products for ESD control for electronics assembly. We cannot make any claims as to the health benefits of grounding the human body.
Thank you so much sir …I have one doubt , when you are checking the ESD on Matt by SRM meter you are connected the electrodes (yellow colour object) to SRM ,I want to know y it is connected & purpose of connecting the electrode
The ESDA describes the design and use this type of electrode in the TR53-01-22 document. The TR53-01-22 is a complimentary downloaded at ESDA. You might also find useful information on the video of our surface resistance meter.
Don't you suppose to have Wristband attached to the ground via the mat.
if human body is electrostatic charge what is the body resistance?
The important thing to understand is the human body is a conductor (measured in ohms of resistance) and the electro-static charge is measured in volts. Because the human body is a conductor, a static charge can be induced onto it. An ungrounded body can then act as a capacitor to hold the charge.
Can electrostatic charges be removed from charged plastic by rubbing it on the ESD mat?
No. Plastics (unless specifically designed with conductive compounds) are insulators. Insulators must adhere to the 1 inch/12 inch requirement from ESD susceptible devices or ionization must be used to neutralize the charge on the insulator. Even if the plastic was conductive, rubbing it would be ineffective. Conductors must be continually grounded.
Teacher bus english or quick books I need
Ecomincs was in rose woods for hoilday
Very informative video, very well explained, many thanks to you sir 🙏
I’ve killed so many phones by holding them bare, electrical devices keep freezing or don’t work for me when I hold them for long but if someone else touches it, it magically works again. :( thanks for the info!!
Hi Get a wire and keep rounding yourself out to the ground
Hi Gregg, My name is Jeremy Suttie, I'm a Quality Manager for an In-flight Entertainment company and had a question about your Personal Safety slide, bullet three. You mention the "standard" outlines bullet three, "Grounding not recommended over 250 volts - energized equipment, HIPOT testing, etc.", but I am unable to find this information within the ANSI/ESD S20.20-2014 document. Is this the "standard" you're referring to or another? Appreciate the assistance!
Thanks for the clear and informative video!
I have one of the 19492 models and after zeroing it doesn't seem to work on anything even an statically charged balloon.
Wow! Great info thanks for sharing.
Very good Please follow our channel too, Thank you.
Thank you for this thorough explanation.
damn so we generate more volts than a car battery
Great info thanks for sharing Desco and Mr Gregg Heckler
Nice video ! electrostatic field meter ! www.advancetech.co.in/products/ssd-japan/static-charge-meter/dz4
Thank you very much guys!
Horrible music
so isn't a person 'grounded' when they go barefoot on the earth?
Technically you could be if the ground you were standing on was conductive enough. For instance, moist or wet earth, but not sand. You certainly would not want to be barefooted in a production environment, and you would have no safety resistance to protect you from electrical shock.
@@DescoESDControl ; Thank you. I was shocked pretty severely when I was a child, it knocked me out for 2 hours. I am very careful around electricity.....LOL!!
I was thinking about both a esd bench mat and floor,both with grounding snaps,but I was wondering,would it be safe to have both a heel grounding strap connected to the floor mat and connected to a hip to wrist strap?,also please note:I am planning on having four ground wires,two for the bench mat and two for the floor mat and connected to the same receptacle as the bench mat.
The best solution would be to keep each part of the your grounding system separate and not daisy chained together as suggested. If you were to connect your heel strap to your wrist strap which is then connected to the floor mat, the minute you lift your foot off the ground, you would become ungrounded while working at that particular workstation. I would keep them separated by having operators plug in their wrist strap while seated or wear their foot grounders while standing. • 09740 - Can be mounted under the workbench for operators to plug in their wrist straps. • Foot grounders are to be worn in combination with the floor mat. As long as the floor mat is grounded, then the person with foot grounders can stand or walk across the floor mat without accumulating a charge.
How do you wash these?
Statshield® smocks must be laundered periodically for proper operation. Desco recommends Woolite. Liquid detergents are better than dry because there is less caking and frictional wear. Use only non-ionic softeners and detergents when laundering. Launder Statshield® smocks in cool or warm water, tumble dry with low heat or hang dry. DO NOT USE BLEACH OR FABRIC SOFTENER. Launder Statshield® smocks by hand or with a washing machine. Use a standard household machine on gentle cycle or use an industrial machine if “Pony” (typically under 200 pound loads) machines are used. It is not recommended to launder these Statshield® smocks in heavy industrial laundry machines because it will lead to premature wear; degrading the ESD properties. Statshield® smocks should be tumbled dry using low heat. The carbon-suffused mono-filament nylon is sensitive to heat and should not be exposed to laundering heat in excess of 120°F. Under normal wearing and recommended washing conditions, Desco Statshield® ESD protective smocks will maintain their usefulness and effectiveness for a minimum of 100 washings.
Thank you Jim. It was a great presentation about grounding carts. One question, if you have epoxic floor or vinyl tile floor is the same behavior about the continuity between the floor and the wheels? Do you need special wheels when epoxic floor is used?
This video is very helpful!!
Are air ionizer safe to run while the worker or technician is in the room?
Operator safety always takes precedent to ESD control. Your facilities safety coordinator/officer should be consulted on any question of safety. Desco ionizers are intended to be used with an operator present. There are no known risks associated with using Desco ionizers.
@@DescoESDControl thank you
I just got an ionizer today and i can already feel the benefit. I can breath much easier.
hellow iron man
Is this to help with dust?
Thanks for the video. But shouldn’t you warn about being barefooted when wearing a grounding wristband ? I remember i got a shock when i was barefeet on tiles wearing my wristband but never got any shock when wearing it while laying on my bed. Being barefooted caused that or is it just me ?
If you were wearing a wrist strap and standing barefoot on conductive flooring of some type, you would only be protected from shock hazard up to 250 with the 1 megohm safety resistor in the strap cord. This would not be recommended even if you could go barefoot in a production environment.
@@DescoESDControl thank you
Thanks for the video, I found it to be very interesting. What type are these? type C or Type D? I am trying to compare it to the bags from www.crohmiq.com/ I also am curious to know if you think size makes a difference? Thanks in advance
is it effective to wrap my circuit breaker panels with A shielding roll to prevent emf from spreading
This is not what our products are intended for. However, the metal panel and cabinet that the circuit breakers are mounted to would have a similar effect in shielding EMI.
Should body voltage not be in the order of milli Volts and not Volts ??? ................you are measuring 130 vAC on the body !!!!!......ouch .
Yes 130 vAC would hurt - a lot. Thankfully it is not AC volts. Static electricity is different from current electricity (AC or DC). Static electricity has a very low amount of current (measured in amperage). As explained here “voltage is a measure of the pressure that allows electrons to flow, while amperage is a measure of the volume of electrons. An electrical current at 1,000 volts is no more deadly than a current at 100 volts, but tiny changes in amperage can mean the difference between life and death when a person receives an electrical shock.
When it comes to measuring the amount of static voltage on the human body, the voltage is DC not AC. It is measured in volts as the typical test equipment used will not measure millivolts. Also, voltage that low would not be a threat to ESD sensitive electronic components. Also note, that there is no load or amperage in a typical ESD event, so the person is not susceptible to danger as could be with AC voltage.
@@DescoESDControl I understand that static current is always measured in millivolts of alternating current and not in direct current. Grounding experts do it this way when they walk barefoot on the ground.
Which mat do you use in this video? What is its material?
The mat used in this video is Desco Statfree T2™, which has recently been replaced with Desco Statfree T2 Plus™ (item 66466). It is a Dissipative Dual Layer Rubber material.
@@DescoESDControl Thank you for your answer. We need ESD that should not wrinkle. There are other alternatives in your website: vinyl and G2 rubber. What are the difference between these materials? Which one is softer one such that it should not wrinkle over time?
@@sogut37 We are assuming by wrinkle you mean a crease type situation somewhere on the mat. Under normal use in an electronics manufacturing type environment none of our matting products should wrinkle. As you noted, we have both rubber and vinyl matting materials. You want to select a mat specifically for table use (G2 is a floor mat and is not recommended for table use because of it’s lower resistance). Below are the links to our rubber table mat product and our vinyl table mat product. Rubber - T2 Plus - Mat Kits might be your best choice since each mat includes a ground cord - desco.descoindustries.com/DescoCatalog/Worksurface-Mats/Rubber/Statfree-T2-Plus-Dual-Layer-Dissipative/ Vinyl - Z2 - Same situation - choose a 2’x3’ or 2’x4’, they come with a ground cord - desco.descoindustries.com/DescoCatalog/Worksurface-Mats/Vinyl/Statfree-Z2-Dissipative-3-Layer/
It is tough trying to watch video while reading.
Thanks for sharing the video Deck Coatings at best price. Innovative polycoats is deck coating service provider in pune. Deck Coatings service, Deck Coatings service provider in India. Deck Coatings - Innovative polycoats www.innovativepolycoats.co.in/DeckCoatings.html